MATERIAL CODES AND TEST POINTS: TABLE 3


TABLE III - MATERIAL CODES AND TEST POINTS
MATERIAL
GAGE
STACKING FACTOR
MATERIAL CODE
B MAX KILOGAUSS
TEST POINT
TYPICAL DATA
B(KG)
f (HZ)
W/LB
VA/LB
MICROSIL
1 mil
.83
MM
15.0
10
400
8.0
16.5
2 mil
.89
ML
16.0
15
400
12.7
20.0
4 mil
.90
MH
17.0
15
400
10.0
13.1
4 mil
.90
MTH*
17.0
15
400
12.0
22.0
4 mil
.90
MZ
18.0
17.6
400
16.9
48.0
4 mil
.90
MTZ*
18.0
17.6
400
18.0
68.0
7 mil
.90
MJ
18.0
17.6
400
15.0
30.0
7 mil
.90
MTJ*
18.0
17.6
400
17.0
50.0
9 mil
.95
MAZ, MSZ
18.0
17.6
60
1.1
2.1
9 mil
.95
MTAZ, MTSZ*
18.0
17.6
60
1.2
2.6
12 mil
.95
MA (<10 LB.)
18.0
15.0
60
.9
1.7
12 mil
.95
MS(>10 LB.)
18.0
15.0
60
.9
1.7
12 mil
.95
MTA, MTS*
18.0
15.0
60
1.1
2.5
Supermendur
4 mil
.90
MXH
21.0
21.0
400
15.0
36.0
4 mil
.90
MTXH*
21.0
21.0
400
20.0
62.0
Superperm 49
1 mil
.83
MBM
15.0
12.0
400
3.0
3.5
2 mil
.89
MBL
15.0
12.0
400
3.8
4.0
4 mil
.90
MBH
15.0
12.0
400
4.2
4.5
6 mil
.90
MBG
15.0
12.0
400
4.5
4.8
Superperm 80
1 mil
.83
MCM
7.0
4.0
400
0.18
0.70
2 mil
.89
MCL
7.0
4.0
400
0.20
0.70
4 mil
.90
MCH
7.0
4.0
400
0.25
0.75
6 mil
.90
MCG
7.0
4.0
400
0.30
0.80

* For Three Phase MT - Cores: Testing will be performed under single conditions and totaled to replicate three phase conditions. The exception to this test method would be when a customer provides a set of three phase.