What's New    
 
Tape Wound Core Catalog

Transformer Lamination Catalog

Cut Core Design Manual

 

TABLES: TEST LIMITS, STACKING FACTORS


TABLE VIII - TEST CONDITIONS APPLICABLE TO CCFR LIMITS
Performance Designation Frequency Hertz Peak Excitation (Oersteds) B1 for Measurement of H1 (Gausses) B2 for Measurement of H2 or H-H2-H1 (Gausses)
For Bm and Br/Bm For H1 and H
SuperSquare 80 400 .05 1.0 5,000 10,000
Square 80 400 0.5 1.0 5,000 10,000
Square 50 400 1.0 2.0 10,000 20,000
Microsil (.004 inches and thinner) 400 3.0 6.0 10,000 20,000
Microsil (0.12 inches thick) 60 3.0 6.0 10,000 20,000
Supermendur 400 3.5 7.0 14,000 28,000


TABLE IX - STACKING FACTORS - STANDARD VALUES FOR TEST LIMITS
Tape Thickness (Inches) .0005 .001 .002 .004 .006 .012
Stacking Factor (Percent) 50 75 85 90 90 95


TABLE X - 400 HZ CONSTANT CURRENT FLUX RESET TEST LIMITS
See Table XI for values of H.
Performance Designation Core Thickness (Inches) Bm (Gausses*) Bm-Br (Gausses*) H1 (Oersteds)
SuperSquare 80 87 .001 7200-8400 600-1250 .038-.052
.002 7200-8400 725-1350 .034-.048
.004 7200-8400 750-1400 .040-.054
Square 80 81 .001 6800-8200 560-1500 .025-.052
.002 6800-8200 700-1600 .023-.045
.004 6800-8200 770-1800 .025-.050
Square 50 46 .001 14,000-15,500 140-1000 .15-.25
.002 14,000-15,500 140-1050 .15-.25
.004 14,000-15,500 140-1150 .18-.30
Microsil (Bare or Cased) 33 .001 13,000-16,000 2000 max. 1.20 max.
.002 15,000-18,000 2500 max. .70 max.
.004 15,000-18,000 3500 max. .60 max.
.012** 15,000-18,000 4000 max. .35 max.**
Microsil-Selected 34 .004 17,500-18,500 3500 max. .60 max.
Supermendur 107 .002 20,000-22,000 1000-2000 .55-.75
.004 20,000-22,000 1000-2000 .50-.70


TABLE XI - MAXIMUM VALUES OF H BY ID/OD RATIO
Performance Designation
Tape Thickness (inches)
Maximum H (Oersteds) at 400 Hertz
.600-.649 .650-.699 ID/OD Ratio .700-.749 .750-.799 .800 or Greater
SuperSquare 80 .0100 .0100 .0090 .0085 .0080 .0070
.002 .0100 .0090 .0085 .0080 .0070
.004 .0150 .0140 .0135 .0130 .0120
Square 80 .001 .0130 .0120 .0110 .0100 .0085
.002 .0130 .0120 .0110 .0100 .0090
.004 .0228 .0195 .0172 .0150 .0130
Square 50 .001 .0435 .0390 .0360 .0330 .0300
.002 .0475 .0450 .0400 .0375 .0320
.004 .0563 .0525 .0488 .0450 .0430
Microsil .001 .240 .205 .195 .185 .175
.002 .1420 .1380 .1340 .1300 .1250
.004 .1530 .1460 .1390 .1320 .1250
.012* .072* .067* .062* .057* .055*
Supermendur .002 .1200 .1100 .1000 .0900 .0800
.004 .1000 .0920 .0850 .0780 .0700


TABLE XII - PERMEABILITY TEST LIMITS - ROUND LOOP MATERIALS
Performance Designation
Frequency (Hertz)
Induction (Gausses)
Thickness (Inches)
Minimum Permeability (Impedance Measurment)
Supermalloy 100 20 .001 55,000
.002 55,000
.004 55,000
.006 55,000
SuperPerm 80 10,000 20 .001 20,000
.002 15,000
.004 10,000
.006 6,000
SuperPerm 49 1,000 40 .001 4,500
.002 4,500
.004 4,500
.006 3,500
Microsil (Epoxy Coated) 60 6,000 .001 5,000
.002 10,000
.004, .006 15,000
.012 20,000


TABLE XIII - GROSS CORE WEIGHT CONVERSION TABLE
Designation
Factor
Designation
Factor
Designation
Factor
Supersquare 80
Square 80
Square 50
1.059
1.059
1.000
Microsil
Supermendur
0.927
0.988
Supermalloy
SuperPerm 49
SuperPerm 80
1.059
1.000
1.059